Sign In | Join Free | My tjskl.org.cn |
|
Brand Name : SG
Model Number : Hall Effect Current Sensor
Certification : VDE,CQC
Place of Origin : Dongguan China
MOQ : Negotiate
Price : Negotiate
Payment Terms : T/T, L/C
Supply Ability : 50000000pcs per month
Delivery Time : Negotiate
Packaging Details : Export package
Working temperature : -40°C~+85°C;
Insulation resistance : >= 500 MΩ;
Rms voltage for AC insulation test : 50Hz 1min 2.5KV
Sample : Available
Keyword : current sensor
working temperature : -20-70℃
Fuse type : Fuse Holder Types
Power supply : DC24V,DC12V,AC220V
Strong Overload Capacity Hall Effect Current Sensor Good Dynamic Performance
Characteristic
CAB500 Series current sensor is based on Sinomags Active Close Loop technology,
with CANBUS digital output. It can be used to measure 500A rated current. Using a proprietary Digital Compensation technology. This product brings the best combination of performance and reliability.
Error ± 0.2A @ ±<30A, Error ±0.5A @ ±<100A; Error ±1.0A @ ±100A-300A; Error ±1.5A @ >±300-500A.
High electromagnetic compatibility against complex electromagnetic interference environment.
Excellent anti magnetic interference.
Can bus output, convenient for system integration.
Ultra-high over current capability
General parameters
Working temperature: -40°C~+85°C;
Insulation resistance: >= 500 MΩ;
Rms voltage for AC insulation test 50Hz 1min 2.5KV Over-voltage 24V/1 minute
Electrostatic discharge voltage 4KV
Installation | Standard rail+Plane screw fixation |
Original side rated current | 50A;100A;200A;500A; 800A;1000A;customization |
Original side measurement range | 100A-1200A |
Rated output | 5V;DC0~20mA;DC4~20mA;customization |
Auxiliary power supply | DC12V,DC24V,DC±12V,DC±15V |
Load capacity | Voltage output:5mA; Current output:6V; |
Linearity | 0.005 |
Accuracy | 0.01 |
Response time | <200ms |
Temperature drift | ≤500PPM/℃ |
Band width | DC~20KHz |
Consumption of current | ≤25mA |
Working temperature | -10℃~+70℃ |
Storage temperature | -25℃~+85℃ |
Isolation pressure resistance | 2.5kV/50Hz,1Min |
Offset voltage | ≤20mvV |
Zero output | ≤0.15mA |
di/dt follow | >50A/uS |
Electrical parameters
Parameter | Symbol | Unit | Specification | Conditions | ||
Min | Type | Max | ||||
Nominal Measuring Range | IPN | A | -500 | 500 | ||
Supply Voltage | UC | V | 7.2 | 12 | 18 | Full accuracy |
Current Consumption @IP=0A | IC | mA | 26 | UC=12V, T=25°C | ||
Current Consumption @IP=500A | IC | mA | 250 | UC=12V, T=25°C | ||
Sensitivity error Accuracy | XG | % | -0.5 | 0.5 | =-40 to 85°C; | |
Offset=0A | IOS | A | ±0.2 | =-40 to 85°C; ± 3 sigma | ||
Linearity error with IPN | εL | % | 0.1 | @room temperature | ||
Temperature coefficient of G | TCG | ppm/ |
![]() |
CAB500 Hall Effect Current Sensor DC24V DC12V AC220V Strong Overload Capacity Images |